Omnitron-systems-technology Converter GXTM User Manual Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Komunikacja Omnitron-systems-technology Converter GXTM User Manual. Omnitron Systems Technology Converter GXTM User Manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Release 3.4

iConverter® GX/TM Media ConverterandNetwork Interface DeviceSTANDALONE AND PLUG-IN MODULEUSER MANUALRelease 3.4

Strona 2 - Table of Contents

3.2.2.5 SW5 - UTP 10/100 Auto/Manual Crossover “AX/MANX”The GX/TM features 10/100 Auto Crossover, which allows it to connect to a switch or a workstat

Strona 3 - 1.1 GENERAL DESCRIPTION

3.3 INSTALLING PLUG-IN MODULES AND CONNECTING CABLESPIa. Carefully slide the module into an open slot in the chassis. Align the module with the insta

Strona 4 - 2.1.2 UTP and Fiber Ports

3.4 CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE PI SATo configure, attach the GX/TM to a DB-9 serial (RS-232) equipped computer with terminal em

Strona 5 - 3.1 OVERVIEW

The Management Options screen will be displayed.PI SAManagement Options iConverter, Serial Agent Network Management 1: Chassis and Module Management

Strona 6 - (Up/Down)

Page 143.4.1 Setting IP and Control PreferencesAn IP address is required for the SNMP manager to address the GX/TM. The factory default setting is192

Strona 7 - UTP Port Configuration Matrix

3.4.1.2 Setting IP Parameters as DHCP ClientTo configure the IP automatically as a DHCP client, select 9 from the Management Options screen. TheOther

Strona 8 -

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and followthe instructions to enter the chassis numb

Strona 9

PI SAIP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1

Strona 10 - 3.2.2.7 SW7, SW8 - Reserved

Page 18PI SA SNMP Preferences Screen iConverter, Serial Agent Chassis Number = 1 SNMP Engine ID 80001CAE

Strona 11

To set User 1 security, select 10 at the SNMP Preferences screen, press <ENTER> and then follow thescreen prompts. To set the User 2 security,

Strona 12 - Serial Connector Pin Outs

Page 2Table of Contents1.0 Overview ...

Strona 13

Page 203.4.3 Management Processor VLAN SupportThe GX/TM Management Processor can independently transmit and receive Management Data with anIEEE 802.1Q

Strona 14

3.4.4 Enabling/Disabling Soft-switch ReloadThe Soft-switch Reload function controls the configurations of the GX/TM and other iConverter modulesmanage

Strona 15

3.4.5 Access the GX/TM RemotelyRemote access to the GX/TM is provided via SNMP, Telnet, FTP or an external serial modem connected tothe Serial Console

Strona 16

PI SAIP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1

Strona 17

When the upload is complete, the GX/TM displays the update status and then automatically restarts withthe newly loaded firmware.3.4.5.4 Updating the G

Strona 18

3.5 VERIFY OPERATION PI SAOnce the module has been installed and configured, per Sections 3.2 - 3.4, verify the module is operationalby viewing the

Strona 19

4.0 DETAILED MODULE CONFIGURATION PI SA4.1 OVERVIEWThe GX/TM has module parameters that require configuration depending on the application. The Mod

Strona 20

PIChassis View 19 Slot iConverter, Serial Agent Chassis Number = 1 Slot Model Type | Slot Model Type 1 8000-0 NMM | 16 N/A 2 8903-1 10/100

Strona 21

PIModule - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Switch ON Condition OFF Condition H/W

Strona 22 - or third-party

4.2 MODULE MANAGEMENT MODEFrom the Module configuration screen, the management mode can be changed. Select option 18 to changethe mode. The manageme

Strona 23

1.0 OVERVIEWThis document describes the installation and configuration of the iConverter GX/TM standalone NetworkInterface Device and plug-in modules.

Strona 24

4.3 PORT CONFIGURATIONThe Port configuration screen provides access to the port level configuration parameters, such as, PortAccess, SFP information,

Strona 25 - 3.5 VERIFY OPERATION

4.3.1 Port AccessThe Port Access option allows the ports to be disabled/enabled while maintaining the port configurationand network linkTo configure

Strona 26 - 4.1 OVERVIEW

PI SASFP Information - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 2 Model Number = 8939-0 Port =

Strona 27

4.3.3 802.3ah ParametersThe 802.3ah parameters can be monitored and/or configured in the 802.3ah Control screen.• 802.3ah OAM State - The 802.3ah OAM

Strona 28

“Incomplete”, Discovery is in process, but is not yet completed.• Multiplexer State - Indicates the Multiplexer state (“Discard”, “Forward” or “Unknow

Strona 29 - 4.2 MODULE MANAGEMENT MODE

4.3.4 802.3ah Events802.3ah events can be accessed by selecting options 8 from the Port configuration screen.PI SA802.3ah Event - iConverter GX/TM iC

Strona 30 - 4.3 PORT CONFIGURATION

4.3.5 Port VLANThe flow of data on the module is controlled by configuring the Port VLAN settings. The block diagramillustrates the flow of both the m

Strona 31 - 4.3.2 SFP Information

PIModule - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Port VLAN Path Setup Slot Number = 2

Strona 32

4.3.6 Tagged VLANThe GX/TM supports the IEEE 802.1Q tag VLAN packet tagging and un-tagging and the 802.1p Quality ofService priority standards.Tag con

Strona 33 - 4.3.3 802.3ah Parameters

PITag VLAN Control - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 2 Model Number = 892

Strona 34

2.0 PORT STRUCTURE2.1 OVERVIEWThe front panel of the GX/TM provides access to the management (serial console), UTP and fiber ports.The fiber port wil

Strona 35 - 4.3.4 802.3ah Events

4.3.7 VLAN Membership TableThe VLAN Membership Table lists the permitted VLAN ID (VID) for each egress port on the module.Only packets that are assign

Strona 36 - 4.3.5 Port VLAN

PIMembership Entry - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8923-1

Strona 37

PIMembership Entry - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8923-1

Strona 38 - 4.3.6 Tagged VLAN

4.3.8 cNode LoopbackThe GX/TM has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agentrecognizes measurement packets an

Strona 39

PI SAPort StatisticModule - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8923-1

Strona 40 - 4.3.7 VLAN Membership Table

5.0 GX/TM SPECIFICATIONSPlug-in Module Standalone Tabletop Standalone Wall-MountDescription 10/100/1000BASE-T UTP to 1000BASE-X Fiber Media Converter

Strona 41

6.0 TROUBLESHOOTING GUIDE6.1 OVERVIEWThe GX/TM module has several LED indicators available to assist in the determination of problems. Referto Sectio

Strona 42

6.1.3 UTP IssuesProblem:The UTP link LED does not illuminate after installation is complete.Possible Causes:A. Confirm that the UTP cable is connected

Strona 43 - 4.3.9 Port Statistics

7.0 WARRANTYThis product is warranted to the original purchaser against defects in material and workmanship for aperiod of TWO YEARS from the date of

Strona 44

19-Module Chassis 5-Module Chassis 2-Module Chassis1-Module Redundant Chassis3.0 INSTALLATION PROCEDURE3.1 OVERVIEWThe following steps outline the

Strona 45 - 5.0 GX/TM SPECIFICATIONS

3.2 CONFIGURING DIP-SWITCHES PI SAThe GX/TM plug-in module has two board-mounted DIP-switches. The standalone unit has one bank ofDIP-switches. Th

Strona 46 - 6.1.2 Fiber Issues

NOTE: When the fiber optic port operates in Auto-Negotiation mode, the port advertises for Pause.When the fiber optic port operates in Manual mode, P

Strona 47 - 6.1.3 UTP Issues

3.2.1.3 SW3 - UTP Speed Gigabit/10-100 “1000/10-100”When the “1000/10-100” DIP-switch is in the “1000” position (factory default), the UTP always oper

Strona 48

3.2.2 Board-Mounted Bank 2 Settings PI SADIP-switch Bank 2 is available on both the plug-in and standalone modules.PI SASwitch Left (Factory Defaul

Komentarze do niniejszej Instrukcji

Brak uwag